logo

Alfa Laval Base 6

M6-MBase 190PL 4 SEC

Alfa Laval Base 6

M6-MBase 190PL 4 SEC
Lead time on request
  • High energy efficiency – low operating cost
  • Flexible configuration – heat transfer area can be modified
  • Easy to install – compact design
  • High serviceability – easy to open for inspection and cleaning and easy to clean by CIP
  • Access to Alfa Laval’s global service network

Description

Alfa Laval BaseLine is a range of gasketed plate-and-frame heat exchangers used in dairy, food, beverage and other hygienic applications requiring thermally efficient performance. A large range of plate and gasket types is available.

Technical details

Heat recovery
94%
Flow rate primary side
4000 kg/h
Temp primary side
4 → 74 → 4 °C
Pressure drop primarySide
323 kPa
Cooling media
Ice water
Flow rate cooling
6568 kg/h
TempCooling
2 °C
Pressure drop cooling
42 kPa
Heating media
Hot water
Flow rate heating
4955 kg/h
TempHeating
75 °C
Pressure drop heating
40 kPa
Min. CIP flow rate
3200 kg/h
Pressure dropCIP
200 kPa