The Pharma-line is a high quality tubular heat exchanger designed to operate in the pharmaceutical and biotech industries. There are different executions available for different duties and demands. All Pharma-line products are designed in-line with regulations within this industry. It is suitable for heating and cooling of products intended for the pharmaceutical industry, mainly water For Injection (WFI) and Purified Water (PW) and some non-viscous pharmaceutical products.

Technical details

Flow rate tube side (kg/h)
15000 kg/h
Temp. in tube side (°C)
20 °C
Temp. out tube side (°C)
90 °C
Insulation
Yes
Heating media
Steam 3 barg
Steam pressure shell side (barg)
3 barg
Temp. out shell side (°C)
143 °C
Surface roughness
0,4µm EP (Electro polished)
Design pressure (bar)
10 bar
Design temperature (°C)
150 °C
Tube velocity (m/s)
2,4 m/s