Alfa Laval M Line 10

M10-MFHC 289PL 1SEC

Alfa Laval M Line 10

M10-MFHC 289PL 1SEC
Lead time on request
  • High energy efficiency – low operating cost
  • Flexible configuration – heat transfer area can be modified
  • Easy to install – compact design
  • High serviceability – easy to open for inspection and cleaning and easy to clean by CIP
  • Access to Alfa Laval’s global service network
About
Alfa Laval M line is a range of gasketed plate-and-frame heat exchangers used in dairy, food, beverage and other hygienic applications. M line is used when the design pressure is above 10 barg (145 psig) or when long plate packs are required. A large range of plate and gasket types is available.

Documentation

Configuration File (en)UNKNOWN
Drawing (en)UNKNOWN
Spare Parts List (en)UNKNOWN
Ten Top Tips (en)UNKNOWN
Maintenance manual GPHE (en)PDF
Installation manual GPHE (en)PDF

Technical details

Flow rate primary side (hl/h)
300 hl/h
Temp primary side (°C)
98 → 8 °C
Pressure drop primarySide (kPa)
207 kPa
Cooling media
Ice water
Flow rate secondary side (kg/h)
33260 kg/h
Temp. secondary side (°C)
2 °C
Pressure drop secondary side Dairy And Beverage (kPa)
224 kPa
Min. CIP flow rate (kg/h)
20000 kg/h
Pressure dropCIP (kPa)
82 kPa